Product Details:
Parameter To Be Monitored | Humidity and Temperature |
Type Of Data Logger | 2 Caannel |
Material | PVDF |
Color | White |
Weight | 100g |
Connection | wireless |
Usage/Application | Building Automation |
Brand | HK instrument |
Battery | Yes |
Display Type | LCD |
Humidity Accuracy | 2-3% |
RHT relative humidity transmitters are engineered for building automation systems in the HVAC/R industry. The RHT measures relative humidity (rH), and temperature (T). RHT devices are available with large touchscreen display making con???guration of the device quick and easy.
RHT devices include:
• Separate gurable output for each measurement parameter (rH and T)
• Proportional output options including: voltage (0–10 V, 2–10 V) and current (4–20 mA)
• Offset feature enabling field calibration for each measurement parameter (rH, T).
RHT series device options offer:
• 2” x 3” touchscreen display
• Field configurable relay for any of the two parameters
• Modbus configuration
Product Details:
Model Name/Number | DM7276 |
Brand | Hioki |
Warranty | 3 Year |
Digit Display | 8 |
Usage/Application | Lab |
DC Voltage Accuracy | 100mV to 1000V |
Safety Rating | CAT III |
Dimension | 215 mm (8.46 in) W x 88 mm (3.46 in) H x 232 mm (9.13 in) D (excluding protrusions) |
True RMS/AVG responding | Yes |
Display Type | 4.3-inch, TFT color LCD resistive touch panel |
Standard Accessories | Instruction manual x 1, power cord x 1, application disk (CD-R) x 1 |
Diode Test | Yes |
Continuity Check With Beeper | Yes |
Data Hold | Yes |
Auto Power Off | No |
Low Battery Indication | No |
Management Support Functions | Comparator, BIN, absolute value judgment, label display, statistics, measurement information, commun |
Standards | Safety: EN61010 EMC: EN61326, EN61000 |
Integration Time | Integration time unit: PLC/ms (PLC setting: 0.02/0.2/1/10/100, ms setting: 1 ms to 9999 ms) |
Internal Memory | 5000 data points (voltage, temperature, elapsed time), 30 panel data points |
Contact Check | Check signal: 10 mVrms, threshold value: 0.5 nF to 50 nF (Cannot use in the 100 V/1000 V ranges), Co |
Measurement Parameters | DC voltage ( conversion method), Temperature (when using the Z2001 thermistor sensor) |
Measurement Support Functions | Smoothing function, Null, temperature compensation, scaling, over-range display, self-calibration, a |
Measurement Range | -10.0 DegreeC to 60.0 DegreeC (14.0 DegreeF to 140 DegreeF) |
The DM7276 Precision DC Voltmeter delivers superior measurement accuracy of 9 ppm (0.0009%), an accuracy level that is demanded by advanced applications such as aging tests of lithium-ion batteries. Other key features include contact check to maximize measurement reliability, binning and temperature compensation, making the voltmeter ideal for developing and manufacturing Li-ion batteries, electrical double-layer capacitors, electric vehicle components, and other next generation devices.
Key Features:
• High-accuracy model with 1-year 9ppm Accuracy
• Capacitance contact check (using built-in C-monitor)
• Supports global production with built-in variable power supply
• Built-in EXT I/O, LAN, and USB
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | CM 4373 |
Battery | LR03 |
DC Current - Sensing Range | 600A/2000A |
AC Current - Sensing Range | 600A/2000A |
DC Voltage | 1500V |
Brand | Hioki |
Warranty | 3 Year |
Usage/Application | Industrial |
Jaw Open | 55mm |
Digit Display | 4 Digit |
AC Voltage | 1000V |
Auto Power Off | Yes |
Features | AC=DC Current |
Resistance | 600Kohm |
Accuracy | 1.3% |
Safety Rating | CAT IV 600 |
Low Battery Indication | Yes |
Color | Blue |
Additional Information:
Product Details:
Model Name/Number | RHT Duct |
Brand | HK Instrument |
Voltage | Battery Operated 9V |
Operating Range | DegreeC, % rH |
Accuracy | 0.5 |
Measuring Parameter | Humidity and Temperature |
Usage/Application | Pharma |
RHT Duct is a relative humidity transmitter with temperature output installed in air ventilation duct. Illuminated display ensures easy readability also from a distance. The RHT has a screwless lid and an easily adjustable mounting flange that make the installation of the device easy.
RHT Duct series devices include:
• Separate output for each measurement parameter (rH and T)
• Offset feature enabling field calibration for each measurement parameter (rH, T)
• Mounting flange
RHT Duct series device options offer:
• Clear backlit display
• Modbus RTU interface
• 4-20 mA proportional output
Product Details:
Model Name/Number | SM7420 |
Range | 50 ohm to 2x10^19 Ohm |
Brand | Hioki |
Resolution | 0.1 fA |
Accuracy | 0.5% rdg |
Current | 20pA-2mA |
Manufactured By | Hioki |
Display | LCD (8 lines of 30 characters), with backlight, high voltage warning indicator |
Number of Channels | 4ch |
Functions | CH independent low capacity contact checks, CH independent cable length correction, CH independent j |
Accessories | Power cord x1, Instruction manual x1, CD-R (Communications command instruction manual, USB driver) x |
Dimensions | 330 mm (12.99 in)W x 80 mm (3.15 in)H x 450 mm (17.72 in)D |
Weight | 6.5 kg |
Resistance Measurement Capabilities | 50 Ohm to 2 x 10 ^19 Ohm |
Measurement Time Setting | Delay: 0 to 9,999 msec |
Interfaces | USB, RS-232C, or , GP-IB |
Power Supply | 100 to 240V AC , 50/60 Hz, 45 VA |
Product Details:
Accuracy | +- 1.5% of reading or +- 1.5 C, whichever is greater |
Weight | 65g with Cable |
Ambient Temperature Range | 0 DegreeC to 70 DegreeC |
Emissivity Setting | Adjustable 0.2 to 1.0 |
Min Temperature Span (Voltage Output) | 100 Degree C |
Max. Supply Voltage | 28 V DC |
Min. Supply Voltage (at Sensor) | 12 V DC (for 10 V output) / 6 V DC (for 5 V output) |
Response Time | 125 ms (90% response) |
Cable Length | 1 metre standard (longer lengths available to order) |
Repeatability | +- 0.5% of reading or +- 0.5C, whichever is greater |
Max Temperature Span (Voltage Output) | 1000 Degree C |
Spectral Range | 8-14 |
Max Current Draw | 6 mA |
Field of View | 15:1 (see Field of View Diagram) |
Configuration | Via built-in display and controls |
Temperature Output | Voltage: 0-5 V DC or 0-10 V DC output, linear with measured temperature, rescalable |
Alarm Output | Open collector alarm output with temperature threshold and hysteresis, configurable |
Temperature Range | 0 to 1000 DegreeC |
Product Details:
Model Name/Number | FT3424 |
Measuring Range | 0- 200000 Lux |
Usage/Application | Industrial |
Brand | Hioki |
Resolution | 0.1 Lux |
Type | Silicon photo diode |
Accuracy | 2% rdg |
Photo Detector | Silicon photo diode |
Warranty | 3 Year |
Photo Diode Sensor | Silicon photo diode |
Accessories | sensor cap carrying case,Usb cable |
Product Details:
Model Name/Number | PM180 |
Display Type | 2.83" (72 mm) resistive touch TFT, 320 x 240 pixels, backlit |
Weight | 280 g |
Logging Interval | 1 to 86,400 seconds (1 day) |
Signal Processing | Average, peak hold, valley hold, minimum, maximum |
MicroSD Card | Max. capacity: 32 GB (not included) |
Alarm Configuration | 12 alarms (2 per sensor) with adjustable level, individually configurable as HI or LO |
Variables Logged | Target temperature, sensing head temperature, alarm events |
Dimensions | 98(w) x 64(h) x 36(d) mm excluding cable glands |
Ambient Temperature Range | 0 to 60 Degree Celsius |
Relative Humidity | Maximum 95%, non-condensing |
Compatibility | PyroMiniBus (all models), PyroBus (all models), PyroMini (-BB and -BRT models) |
Maximum Current Draw | 100 mA |
Configurable Parameters (global) | Temperature units, date and time, data logging, graph channels, alarm logging |
Display Sample Period | 120 ms per sensor (720 ms in total for 6 sensors) |
Configurable Parameters (per sensor) | Signal processing, emissivity setting, reflected energy compensation, alarms |
Internal Clock Battery | 1 x BR 1225 3V (not included) |
Supply Voltage | 10 to 30 V DC |
Configurable Parameters | Sample period, number of samples, scheduled start date and time |